Testing pipes
Pipe testing, identification and marking
- Pipe wall thickness should be tested in accordance with AS 2550.15 Cranes - Safe use - Concrete placing equipment (non-Queensland Government link) .
- Ultrasonic testing may not be appropriate for twin wall pipeline. Other testing methods include the use of thickness testing callipers, increased inspection and increased monitoring of use, in terms of volume and type of concrete pumped.
- Piping which has a wall thickness less than the recommended thickness for the pumping design pressure should not be used.
- All pipeline segments shall be clearly identified with a permanently fixed unique identification mark or number, prior to being placed in service, showing the details required in accordance with
AS 1418.15 Cranes (including hoists and winches) concrete placing equipment (non-Queensland Government link) . - The pipe logbook shall record wall thickness and pressure details, in accordance with AS 1418.15 Cranes (including hoists and winches) concrete placing equipment (non-Queensland Government link) .
For more detailed information on pipe testing, identification and marking, check Section 5.12 of the Concrete Pumping Code of Practice 2005.